|

206430 6t-wsk 6" Wall Sprt.kit
Selkirk - Metalbest 6" WALL SUPPORT KIT
Also useful where pipe connections pass through combustible interior or exterior walls Designed to carry chimney heights to 60' at 2" from the wall For use with the insulated tee as an internal or external support where the chimney has a lateral connection
View Details
|
42254 |
206430 6t-wsk 6" Wall Sprt.kit |
1 |
99.95 |
/ EA |
206430 |
|
|

206450 6t-lb 6"locking Band
Selkirk - Metalbest 6" LOCKING BAND
Inward flanges fit into grooves at pipe joints Mandatory for all exposed joints Prevents accidental uncoupling and adds support Recommended for all chimney joints Used to increase stability of chimney :All insulated pipe lengths are furnished with a Locking Band. Locking Bands are pre-assembled with captured nut and screw.
View Details
|
42279 |
206450 6t-lb 6"locking Band |
Please Call for Availability |
16.95 |
/ EA |
206450 |
|
|

206463 6t-iwt 6" Insul. Wall Thm
Selkirk - Metalbest 6" INSULATED WALL THIMBLE
206463 - 6TIWT, EW No. 726-3171 requires a 14-1/8' x 14-1/8" opening 208463 - 8TIWT, EW No. 726-3210 requires a 16-1/8' x 16-1/8" opening New insulated wall thimble installs quickly and eliminates the need for using individual firestops The round shielding acts as a radiation shield and provides the required 2" air space clearance to combustibles The two sections telescope to accommodate 6 to 11" wall thickness
View Details
|
4206702 |
206463 6t-iwt 6" Insul. Wall Thm |
1 |
59.95 |
/ EA |
206463 |
|
|

206480 6t-fc 6" Finish Collar
Selkirk - Metalbest 6" FINISH COLLAR
Black matte finish Fits over lower end of suspended insulated chimney pipe to provide a finished appearance Used to attach T-DSA Smoke Pipe Adapter to lower end of chimney or to an insulated tee
View Details
|
42291 |
206480 6t-fc 6" Finish Collar |
3 |
19.95 |
/ EA |
206480 |
|
|

206800 6t-ct 6" Chim.topper
Selkirk - Metalbest 6" CHIMNEY TOPPER
3 legs slide down over the outside of the chimney Cinch band is positioned over the legs and tightens to hold the top firmly in place Dome design excludes rain and leaves EW No. 104-1894 leg diameter (A) =8", Dome (B) "12" and height (C) = 5-1/2" EW No. 104-2505 leg diameter (A) =10", Dome (B) "16" and height (C) = 7" Lower skirt deflects wind for proper chimney draft
View Details
|
42260 |
206800 6t-ct 6" Chim.topper |
2 |
89.99 |
/ EA |
206800 |
|
|

206810 6t-sc 6" Storm Collar
Selkirk - Metalbest 6" STORM COLLAR
Designed to fit on the round chimney pipe just above the roof flashing Upper edge of the Storm Collar should be waterproofed with silicone sealer to prevent any water leakage
View Details
|
42263 |
206810 6t-sc 6" Storm Collar |
2 |
17.95 |
/ EA |
206810 |
|
|

206825 6t-af6 6" 2/12-6/12 Rflas
Selkirk - Metalbest 6" 2/12 - 6/12 ROOF FLASHING
Diverts rain and snow down the roof and away from the chimney system Use to seal opening where chimney penetrates roof
View Details
|
42265 |
206825 6t-af6 6" 2/12-6/12 Rflas |
2 |
67.95 |
/ EA |
206825 |
|
|

206830 6t-af12 6"6/12-12/12rflas
Selkirk - Metalbest 6" 6/12 - 12/12 ROOF FLASHING
Diverts rain and snow down the roof and away from the chimney system Use to seal opening where chimney penetrates roof
View Details
|
48485 |
206830 6t-af12 6"6/12-12/12rflas |
1 |
94.95 |
/ EA |
206830 |
|
|

206490 6t-ais 6" Attic Ins.shld.
Selkirk - Metalbest 6" ATTIC INSULATION SHIELD
Required to guard against the hazard of blown-in or blanket insulation filling any framed opening or contacting the chimney and possible contact of combustibles against the chimney
View Details
|
40759 |
206490 6t-ais 6" Attic Ins.shld. |
2 |
92.99 |
/ EA |
206490 |
|
|

6t-it 6" Insulated T W/cap
Selkirk - Metalbest 6" INSULATED TEE
Designed for air-tight wood stoves Insulated tee cap, removable from bottom opening, is included Maximum supportable height is 50' Stainless steel Use for starting chimneys indoors or outdoors using wall support assembly or a masonry pier
View Details
|
42246 |
6t-it 6" Insulated T W/cap |
1 |
199.95 |
/ EA |
206100 |
|
|

206420 6t-rsp 6" Roof Support
Selkirk - Metalbest 6" ROOF SUPPORT KIT
Fits all roof pitches Ideal support assembly for freestanding fireplaces in open cathedral ceiling installations Maximum length of chimney which can be suspended below is 20' Maximum total length is 30' Requires simple framing
View Details
|
42248 |
206420 6t-rsp 6" Roof Support |
2 |
149.95 |
/ EA |
206420 |
|
|

206240 6t-dsac 6"pipe Adap.w/cpl
Selkirk - Metalbest 6" SMOKE PIPE ADAPTER W/COUPLER
Dripless smoke pipe adaptor with coupler (DSAC) For new installations Install by twist-locking coupler into first section of Model SSII type HT chimney pipe
View Details
|
48483 |
206240 6t-dsac 6"pipe Adap.w/cpl |
2 |
59.95 |
/ EA |
206240 |
|
|

206400 6t-ap 6" Anchor Plate
Selkirk - Metalbest 6" ANCHOR PLATE
Provides secure attachment for the chimney to smoke chamber outlet on masonry fireplaces, reducing footing loads and speeding construction Retains chimney with twist-lock connection Stainless steel and heavy gauge steel construction for long life
View Details
|
42204 |
206400 6t-ap 6" Anchor Plate |
1 |
59.99 |
/ EA |
206400 |
|
|

206622 6" Thru Wall Sup.kit.
Selkirk - Metalbest 6" THRU-THE-WALL SUPPORT KIT SURE-TEMP Type HT Thru-The-Wall Support Kit (TWK) For a wall-supported chimney system with a horizontal connector passing through an exterior wall, connecting to a Tee and running vertically up the exterior wall to termination above the roof line. The Thru-the-Wall Support Kit provides all necessary parts for a complete installation with the exception of required Insulated Pipe Lengths to reach your desired chimney height. One Wall Band (WB) is included in the kit. Additional Wall Bands could be required if vertical chimney run is more than 16 feet high. In the event that your vertical chimney run penetrates the roof eave, your installation could also require an Adjustable Flashing (AF) and Storm Collar (SC). Includes;
12" insulated pipe Finish collar Insulated tee/plug Insulated wall thimble Round top Smoke pipe adapter Wall band Wall support kit
View Details
|
4091609 |
206622 6" Thru Wall Sup.kit. |
1 |
589.00 |
/ EA |
206622 |
|
|

6" Ptchd Ceiling Support
Selkirk - Metal Best 6" PITCHED CEILING SUPPORT KIT SURE-TEMP Type HT Pitched Ceiling Kit (PCK) For installation of a chimney in a cathedral or pitched ceiling such as standard A-Frame construction. The Pitched Ceiling Support Kit provides all necessary parts for a complete installation with the exception of the required Insulated Pipe Lengths and Adjustable Flashing (AF). Roof Support Package (RSP) comes with one 18" pipe length as part of the support. Includes:
Adjustable pitched ceiling plate Finishing collar Material: Stainless Steel, Galvanized Steel, Aluminum Roof support package Round top Smoke pipe adapter Storm Collar
View Details
|
4091617 |
6" Ptchd Ceiling Support |
1 |
299.95 |
/ EA |
206621 |
|